Alarm System Installer Codes

Posted in: admin12/11/17Coments are closed

Glossary of Fire Alarm and Security System Terminology. BYPASS When an INPUT DEVICE such as a motion sensor is electronically neutralized so that a FAULT on that sensor does not trigger an OUTPUT DEVICE. In the case of a MOTION SENSOR, this allows the occupants to freely move about while the BURGLAR ALARM SYSTEM is ARMED. In the case of a FIRE ALARM SYSTEM, a TROUBLE indication should register when an INPUT DEVICE is BYPASSED. Premier 412 816 Master User Manual About the Alarm System INS1415 3 1. About the Alarm System Introduction Your alarm system consists of a control panel, one or more. Home Alarm System Monitoring Service from 8 a Month Noterm contract nationwide home alarm monitoring services saves you money on that monthly alarm bill with. IDS Alarm Services Inc. Commercial Security Systems and business security services. AlarmsBC presents alarm systems, home security,alarm equipment,free user manuals,alarm verification,false alarms alarm security companies,INSTALLATION ANS SERVICE. Back to Top. CANASA Short for CANADIAN SECURITY ASSOCIATION. This is an association of alarm companies in Canada that advocates for the industry in matters concerning local law enforcement response, certification, standards, etc. User Account Control An Unidentified Program. For more information, click here. CELLULAR TRANSMITTER, GSM, or LINE CUT ALARM An OUTPUT DEVICE triggered by the ALARM SYSTEM when its ARMED or it detects the sudden loss of the protected premises telephone line. It signals either of these events to the CENTRAL STATION so that an appropriate response can be instituted. CENTRAL STATION A facility that provides monitoring services for signals generated by their customers ALARM SYSTEMS. Some CENTRAL STATIONS are listed by independent testing or certification facilities like UL, ULC, FM, NACOSS. CID A communications format developed by Ademco Division of Honeywell that utilizes bursts of DTMF tones in order to transmit alarm events over a standard telephone line POTS or cellular network. Also called Contact ID. Offer/p/442208_p.jpg' alt='Alarm System Installer Codes' title='Alarm System Installer Codes' />Back to Top. Download Mobile Suit Gundam Oo Sub Indo. CIS Common Intelligibility Scale a measure of a sound systems intelligibility. CLASS A CIRCUIT Type 6 or Style Z Loop A type of alarm circuit which has four physical terminations in a common controls input, output, or DCL SLC circuits and which employs a single continuous two wire loop path from the panel to the first device, on through to the last device, returning to the panel via a separate entry point in the enclosure. A break or open in the wire along any part of the loop will result in a trouble condition at the panel but will not otherwise affect the operation of any device connected in the loop. This type of circuit is commonly employed in an addressable communications circuit also termed SLC or DATA COMMUNICATION LINK RISER from which analogue devices on each floor of a multiple story OCCUPANCY are quite often T TAPPED through individual ISOLATION MODULES. A wire short imposed on a CLASS A SLC or DCL circuit will result in failure of both segments of the circuit. A similar condition on a conventional INITIATING CIRCUIT will result in an alarm condition that a RESET of the common control will not clear while a TROUBLE indication will be displayed if an OUTPUT CIRCUIT is shorted. CLASS B CIRCUIT Type 4 or Style Y Loop A two wire input or output circuit which terminates in an END OF LINE DEVICE which provides circuit SUPERVISION. Alarm code displays. Alarm codes appear at the alarm telephone if one has been identified in Administration programming and in the System Test Log, the. Alarm system can talk, supports twoway intercom, thermostat temperature control, dry output with smart control, 30 wireless zones, 4 wired zones, equipped with GSM. An END OF LINE DEVICE is normally not required on a DATA COMMUNICATION LINK or SLC circuit. CLASS A FIRE A fire in ordinary combustibles such as wood, paper, cloth, trash and plastics. Back to Top. CLASS B FIRE A fire in flammable liquids such as gasoline, petroleum oil and paint. Class B fires also include flammable gases such as propane and butane. Class B fires do not include fires involving cooking oils and grease. CLASS C FIRE A fire involving energized electrical equipment such as motors, transformers and appliances. Remove the power and the CLASS C fire becomes one of the other classes of fire. CLASS D FIRE A fire involving burning metals and their chemical oxides. Magnesium, phosphorus, sodium and powdered aluminium the latter is used in solid fuel rockets are the more common examples. Class D fires utilize chemically generated oxidants and as such are extremely difficult to extinguish. In many cases the only method is no method in other words you must allow it to burn itself out and the role of the Fire Fighter is primarily concerned with stopping the possible spread of the fire to adjacent vehicles or structures. Back to Top. CLASS K F FIRE Involve cooking oils, grease and fats. CLOSURE A device or assembly for closing an opening through a fire separation such as a door, and includes all components such as hardware, closing devices, frames and anchors. COMBUSTIBLE LIQUID Any liquid having a flash point at or above 3. C and below 9. 3. C. CONTROL PANEL Is the means by which INPUT DEVICES communicate a fault to the building occupants or a CENTRAL STATION through the activation of a programmed response that may or may not include specific OUTPUT DEVICES. The CONTROL PANEL usually consists of a circuit board also referred to as the MOTHERBOARD or COMMON CONTROL, and is usually housed in a metal box sized to accommodate both it and a standby source of power the BATTERY. INPUT DEVICES, ZONE EXPANDERS, KEYPADS, and OUTPUT DEVICES are connected to the main circuit board. Back to Top. DATA COMMUNICATION LINK DCL also known as SIGNALLING LINE CIRCUIT SLC The means employed by an ADDRESSABLE type control panel to communicate with compatible devices in the field. These may include INPUT DEVICES, OUTPUT DEVICES, ANNUNCIATORS, and remote TRANSPONDERS. DEAD FRONT A cover usually metallic designed to shield sensitive components and terminations within a common control enclosure so as to prevent inadvertent or accidental contact with potentially dangerous voltages by an end user or operator. The cover is removable, usually by qualified service personnel who are familiar with the equipments field connections, for service and troubleshooting purposes. DELAY ZONE A circuit triggered by an INPUT DEVICE that allows the building occupants a set period of time in which to DISARM the ALARM SYSTEM. The time period is adjustable through system PROGRAMMING and usually takes into account how far the KEYPAD is from the main entry door. It is desirable to have the ENTRY DELAY set as low as possible. DE RATING FACTOR A term that usually refers to a multiplier used in the calculation of a BATTERYs standby capacity and which actually serves to determine the correct size of BATTERY to use in a fire alarm system or other mission critical applications. The Building Code will usually specify the amount of stand by and alarm time required based on the type of occupancy. The number takes several factors into account which may affect the batterys capability to produce the required power over its service life. These include age, cell degradation, charger condition, environmental factors, purity of the internal components, construction, etc. The most commonly used DE RATING FACTOR is 1. A sample calculation based on a 3. X2. 4 hoursrequired standby time1. X0. 5 hoursalarm time1. AHIn the above calculation, the minimum battery size to meet the requirements of CODE would be 1. AH Amp Hours.   You should round up to the next highest whole number. It would be suggested  that the nearest size equivalent available from most wholesalers is 1. AH.   Keep in mind that in this example, either 1. AH or 1. 8AH would work if the manufacturers actual de rating factor as suggested in the installation manual for the panel was 1.